|
EJA510A / EJA530A Direct Mount Type Absolute Pressure and Gauge Pressure Transmitter
(Measurement values below are in absolute for EJA510A)
|
A Capsule
|
B Capsule
|
C Capsule
|
D Capsule
|
Range
|
0 to 200 kPa
(0 to 29 psi)
|
0 to 2 MPa
(0 to 290 psi)
|
0 to 10 MPa
(0 to 1450 psi)
|
0 to 50 MPa
(0 to 7200 psi)
|
Span
|
10 to 200 kPa
(1.45 to 29 psi)
|
0.1 to 2 MPa
(14.5 to 290 psi)
|
0.5 to 10 MPa
(72.5 to 1450 psi)
|
5 to 50 MPa
(720 to 7200 psi)
|
Accuracy
|
±0.2%
|
±0.2%
|
±0.2%
|
±0.2%
|
Degrees of protection
|
IP67, NEMA 4X, and JIS C0920 immersion proof
|
Certificates
|
FM, CENELEC ATEX, CSA, IECEx
|
Output
|
4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication
|
Supply voltage
|
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)
|
Ambient temperature
|
-40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
|
Process temperature
|
-40 to 120 deg C (-40 to 248 deg F) (general use type)
|
Maximum overpressure
|
4 MPa
(580 psi)
|
4 MPa
(580 psi)
|
20 MPa
(2900 psi)
|
60 MPa
(8500 psi)
|
Mounting
|
Direct Mounting/2-inch pipe mounting
|
Wetted parts material
|
Capsule
|
Hastelloy C-276
|
Process
connection
|
SUS316L, Hastelloy C-276
|
Housing
|
Cast aluminum
|