123

Yokogawa transmitter Yokogawa EJA210/220 Vietnam Indonesia I

Product Name:*
Name:
E-mail:*
Message:*
Yokogawa EJA210A EJA220A Differential Pressure Transmitter Digital communication Fieldbus protocol

Flange Mounted Differential Pressure Transmitters  Yokogawa Yokogawa EJA210A EJA220A Differential  Pressure Transmitter   with LCD display Vietnam Iran
The high performance flange mounted differential pressure transmitter models EJA210A and 220A can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal corresponding to the measured differential pressure. Models EJA210A and 220A also feature remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM CS™ or XL™ or HART® 275 host.

EJA210A-EMSA1F4C-9CDN/D4/*1 EJA220A-EMSA16J4C-9CDN/D4/*1/2 EJA220A-EHSA16J4C-9CDN/D4/*1/2
EJA210A-EMSA1F4C-9CDN/D4/*1 EJA220A-EMSA16J4C-9CDN/D4/*1/2
EJA220A-EHSA16J4C-9CDN/D4/*1/2 EJA210A-EHSA1F4C-9CDN/D4/*1 EJA210A-EMSA1F4C-9CDN/D4/*1
EJA210A-EHSA1F4C-9CDN/D4/*1 EJA210A-EHSA1F4C-9CDN/KF21/D4/*1 EJA210A-EHSA1F4C-9CDN/D4/*1/M13
EJA210A-DHSA1Z4B –92DN/FS1/D4/M13/T36 EJA210A-DHSA1Z4B–92DN/FS1/D4/M13/T36 EJA210A-EMSA1D2A-90DN/FF1

Specifications

 

EJA210A / EJA220A
Liquid Level Differential Pressure Transmitter

M Capsule

H Capsule

Range

-100 to 100 kPa
(-400 to 400 inH2O)

-500 to 500 kPa
(-2000 to 2000 inH2O)

Span

1 to 100 kPa
(4 to 400 inH2O)

5 to 500 kPa
(20 to 2000 inH2O)

Accuracy

±0.2%

±0.2%

Degrees of protection

IP67, NEMA 4X, and JIS C0920 immersion proof

Certificates

FM, CENELEC ATEX, CSA, IECEx

Output

4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication

Supply voltage

BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)

Ambient temperature

-40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)

Process temperature

-40 to 120 deg C (-40 to 248 deg F) (general use type)

Maximum working pressure

Flange rating pressure

Mounting

Flange mounting

Process flange size

EJA210A: 3-inch (80mm), 2-inch (50mm)
EJA220A: 4-inch (100mm), 3-inch (80mm)

Diaphragm material
(High side)

SUS316L, Hastelloy C-276, Tantalum

Process flange material

S25C, SUS304, SUS316

Housing

Cast aluminum alloy or SUS316 equivalent stainless steel (optional)

 

EJA110A-ELS0A92DB EJA110A-ELS4B92DB EJA110A-EMS4B-97DBX1
EJA110A-DMS5A-27DC EJA110A-EMS4B-72DD/NF11/X1 EJA110A-EMS4B-72DD/X1
EJA110A-EHS4B-72DD/X1 EJA110A-ELS4B-72DDNF11X1 EJA110A-ELS4B-72DDX1
EJA110A-EMS4B-72DDD4X1 EJA110A-ELS4B-97DBX1 EJA110A-EMS4B-97DBX1 EJA110A-EVS4B-92DB-NF11-NS11-KS2-G71 G72 
EJA110-EMS4B-32DD/KS2-E1 EJA110A-EMS4C-9CDJ/D4/*1 EJA110A-EHS5B-97DB/FU1/X1/A/D1/M01/T12
EJA110-ELS4B-32DD/KS2-E1 EJA110A-EMS5B-97EN/FU1/N4 EJA110A-EMS4B-9CDB/FU1/D4
EJA110-EHS4B-32DD/KS2-E1 EJA110A-EMS5B-97DB/FU1/X1/A/D1 EJA110A-ELS4A-97ED/FF1/D1/C1/N4/M11 EJA110A-ELS4A-92DB EJA110A-EMS4A-92DB 
EJA110A-EHS5B-97DB/FU1/X1/A/D1/M01/T12 EJA110A-EMS5B-97EN/FU1/N4 EJA110A-EHS4B-7CDK/FF1/D1/M11/T12  EJA110A-EHS4B-3CDK/FF1/D1/M11/T12
 
 
 
EJA120A-EES4B-72DDNF11X1 EJA120A-DES4A-97DBNF11 EJA120A-EES4B-72DDX1
 
 
 
EJA130A-EMS4B-97DB/FS1/D3/A1/T09 EJA130A-EMS4B-97DB/FS1/D3/A1/T09 EJA130A-EMS4B-97DB/FS1/D3/A1/T09  EJA130A-EHS4B-97DB/FS1/D4/A1/T09 
 
 
 
 
EJA118W-EMSA1CB-AAZ-9CDJ/D4/*1 EJA118W-EMSA1CB-AAZ-9CDJ/D4/*1 EJA118W-FMSA2DBAA0599DB/KS2/D3/M05/T37 EJA118W-FMSA2DBAA0599DB/KS25/D4/M05/T37
EJA530A-EBS4N-02DF EJA530A-EDS4N0-7DF/FS1/D4/A1/T08 
EJA530A-EBS4N-O2DLNS11 EJA530A-FBS4N-09DN/KS25/D3/T07/M15/LC1 
EJA430A-EBS4B-32DD/FU1/D1 EJA430A-EAS4C-9CDJ/D4/*1 EJA430A-EAS4C-9CDJ/D4/*1 EJA430-EBS4C-9CDJ/D4/*1 EJA430A-EAS4C-9CDJ/D4/E1
EJA430AEBS3B97EN/D3 EJA430A-EAS4C-9CDJ/KF21/D4/*1  EJA430A-EBS4C-9CDJ/KF21/D4/*1 EJA430AEBS3B97EN/D3 EJA430A-FAS5B-99DN/KS25/D3/LC1
EJA430A-FBS5B-99DN/KS25/D3/LC1 EJA430A-EBS4B-32DD/FU1/D1 EJA430A-EAS4B-6CDJ/FF1/D1/M11/T03 EJA430A-EAS4B-7CDJ/FF1/D1/M11/T03
EJA440A-ECS4C-9CDJ/D4/*1
EJA210A-EMSA1F4C-9CDN/D4/*1 EJA220A-EMSA16J4C-9CDN/D4/*1/2 EJA220A-EHSA16J4C-9CDN/D4/*1/2 EJA210A-EMSA1F4C-9CDN/D4/*1 EJA220A-EMSA16J4C-9CDN/D4/*1/2
EJA220A-EHSA16J4C-9CDN/D4/*1/2 EJA210A-EHSA1F4C-9CDN/D4/*1 EJA210A-EMSA1F4C-9CDN/D4/*1 EJA210A-EHSA1F4C-9CDN/D4/*1
EJA210A-EHSA1F4C-9CDN/KF21/D4/*1 EJA210A-EHSA1F4C-9CDN/D4/*1/M13 EJA210A-DHSA1Z4B –92DN/FS1/D4/M13/T36 EJA210A-DHSA1Z4B–92DN/FS1/D4/M13/T36 EJA210A-EMSA1D2A-90DN/FF1 
EJA310A-EMS4A-97DA/KF21/C2


About Us

About Us

Xi`an Ao Xin Automation Instrument Co., Ltd., is located in Xi`an city which is the authoritive centre of instrument and gauge .It is cooperated with many related domestic cooperation to research ,sale and service and also obtained the cert of ISO9001-2008. overall strength of the industry 's leading domestic well-known enterprises .Over the years, the company under the "integrity, innovation , development and harmony " principle of service .

Contact Us

Website:http://www.aosoonyb.com
TEL:+
                   +
          FAX:+
Email:xaaxyb@126.com          Email:wsb2828@126.com

Top
点击这里给我发消息 xaqksm wang01-Send Email  Amber
 E-mail:wsb2828@126.com
My status
My status